What a Biosafety Cabinet Does

Biosafety cabinets (BSCs), also called biological safety cabinets, are the primary containment device for work with infectious agents, cell cultures, clinical specimens and other biological materials. They use HEPA-filtered airflow to protect the operator and the room, and Class II and III cabinets also protect the work product from contamination.

Row of Class II biosafety cabinets with work lights on in a busy research lab

Unlike the storage cabinets in our laboratory safety cabinets range, a BSC is a ventilated work enclosure. Choosing one means matching the class to your biosafety level, then planning power, exhaust, placement and yearly certification.

Labs USA supplies NSF/ANSI 49 listed Class I, Class II (Type A2 and B2) and Class III cabinets from leading manufacturers for hospital microbiology, virology, molecular diagnostics, cell therapy and research labs. We coordinate placement, exhaust connections, base stands and certification scheduling.

Biosafety Cabinet Classes Compared

ClassProtectsAirflowTypical use
Class IOperator and environment (not product)Inward airflow at the front opening, HEPA-filtered exhaustEnclosing equipment, low-risk aerosol work
Class II, Type A2Operator, product and environmentAbout 70% recirculated and 30% exhausted through HEPA filters; minimum 100 fpm inflowMost BSL-2 hospital and research work: microbiology, cell culture, clinical specimens
Class II, Type B2Operator, product and environment100% exhausted through a hard duct, no recirculationBiological work that also uses volatile chemicals or radionuclides
Class IIIMaximum containmentGas-tight glove box, HEPA supply and double-HEPA exhaustBSL-3 and BSL-4 agents, high-hazard work
Class III biological safety cabinet glove box with sealed glove ports

Most labs need a Class II Type A2. It covers BSL-1, BSL-2 and many BSL-3 procedures and can usually be installed without a hard duct (a canopy connection is used when small amounts of volatile chemicals are involved).

Class III cabinets are sealed glove boxes for the highest-risk agents and are built to order. For a deeper explanation read our guide to biological safety cabinet classes, including inflow airflow rates.

Class II Types: A1, A2, B1, B2 and C1

Class II typeExhaustChemical useNotes
A1Recirculates most air; room or canopy exhaustNot for volatile chemicalsOlder design, lower inflow
A2About 30% exhausted; canopy connection optionalMinute amounts with canopy exhaustThe standard choice for most labs
B1Hard-ducted; most downflow exhaustedSmall amounts of volatile chemicalsLess common today
B2Hard-ducted; 100% exhaustedVolatile chemicals and radionuclides as approvedNeeds dedicated exhaust fan and HVAC controls
C1Can run recirculating or exhaustedLimited, with exhaust connectedFlexible newer design

Type B cabinets depend on the building exhaust system, so they add mechanical design and cost. We review your procedures with your biosafety officer before recommending a ducted model.

How a Biological Safety Cabinet Moves Air

A Class II biological safety cabinet works by keeping three air streams in balance. Room air is pulled in through the front grille, forming an air curtain that keeps aerosols away from the operator. HEPA-filtered air flows straight down over the work surface so the sample sits in clean air. Below the work surface, the contaminated mix is drawn back through a plenum by the cabinet blower.

In a Type A2 cabinet, roughly 70% of that air is sent back through the supply HEPA filter as downflow, and about 30% leaves through the exhaust HEPA filter on top. A HEPA filter must capture at least 99.97% of particles at 0.3 microns, the hardest size to trap.

Diagram: Esco Airstream cabinet. Green shows room inflow, blue shows filtered air and red shows unfiltered air. Some models, like this one, use ULPA filters, which are finer than HEPA.

Airflow diagram of an Airstream Class II biological safety cabinet showing room inflow, filtered downflow and filtered exhaust

Three ways to connect the exhaust

ConnectionHow it worksTypical cabinets
Recirculating (non-ducted)HEPA-filtered exhaust returns to the roomClass II Type A1, A2 or C1 for biological work without volatile chemicals
Canopy (thimble)A canopy with a small air gap around the exhaust filter housing carries filtered air into the building exhaust. BMBL requires an alarm for low airflow through the canopy.Type A1, A2 or C1 when minute amounts of volatile chemicals are used
Hard-ductedThe cabinet is connected directly to the exhaust duct, preferably with a dedicated fanType B1, Type B2 and Class III

The exhaust connection is decided by your risk assessment, not by the cabinet catalog. It drives HVAC design and cost, so settle it before the room is laid out.

Matching the Cabinet to Your Biosafety Level

The U.S. reference is the CDC and NIH manual Biosafety in Microbiological and Biomedical Laboratories (BMBL), 6th edition. Its Appendix A ties cabinet class to biosafety level and to the protection each class gives.

Biosafety levelWhen a BSC is usedCabinet class (BMBL Appendix A)
BSL-1Work with well-characterized agents that do not cause disease in healthy adults. A BSC is not required, but it is often used to protect cultures from contamination.Class I or Class II
BSL-2Procedures that can create infectious aerosols or splashes are done in a BSC or other physical containment.Class II (most often Type A2); Class I where product protection is not needed
BSL-3Manipulations of infectious materials are done inside a BSC or other containment equipment.Class II or Class III
BSL-4Highest-risk agents with no available treatment.Class III, or Class II when used in a suit laboratory by staff wearing positive-pressure suits

Who decides

  • Your biosafety officer or institutional biosafety committee sets the biosafety level and approves the cabinet type through a risk assessment.
  • Labs USA matches the class, type, width and exhaust connection to that decision and plans the room around it.
  • For room features beyond the cabinet, see our BSL-2 lab design requirements guide.

Biosafety Cabinet vs. Fume Hood

This is one of the most common lab planning questions. The short answer: a biosafety cabinet protects against biological hazards; a chemical fume hood protects against chemical vapors. They are not interchangeable.

Side-by-side comparison of a biosafety cabinet with HEPA filters and a chemical fume hood with exhaust ductwork

Need both biological and chemical protection? A Class II Type B2 cabinet exhausts 100% of its air, allowing limited use of volatile chemicals alongside biological work.

FeatureBiosafety cabinetChemical fume hood
Primary protectionBiological agents (bacteria, viruses, fungi)Chemical vapors and fumes
HEPA filtrationYes, supply and exhaustNo, dilution exhaust only
Product protectionYes (Class II and III), sterile downflowNo, room air sweeps the work
Chemical useLimited (small amounts in A2; more in B2)Yes, designed for chemical work
Hospital useMicrobiology, virology, cell therapy, pharmacyPathology (formalin), chemistry, toxicology

Compare in detail in our PCR hood vs. biosafety cabinet guide and fume hoods for clinical and medical labs.

Biosafety cabinet vs. laminar flow clean bench vs. PCR workstation

All three use HEPA filters, which is why they get confused. Only the biosafety cabinet protects the person doing the work.

FeatureBiosafety cabinet (Class II)Laminar flow clean benchPCR workstation
Protects the operatorYes, inward air curtainNo, filtered air blows toward the userNo
Protects the sampleYes, HEPA downflowYesYes, plus UV for DNA decontamination
Safe for infectious agentsYes, at the approved biosafety levelNoNo
Typical useMicrobiology, cell culture, clinical specimensSterile, non-hazardous prep such as media or electronicsClean PCR set-up

If a clean bench or PCR hood is all you need, see the store workstations further down this page and our PCR hood vs. biosafety cabinet guide.

Sizes, Options and Specifications

  • Nominal widths: 3, 4, 5 and 6 ft (about 0.9 to 1.8 m). Four- and six-foot cabinets are the most common in hospital labs.
  • Sash: vertical sliding sash is standard; hinged sashes are available on some models.
  • Services: gas and vacuum valves, UV lamps, electrical outlets and IV bars.
Airstream Class II biological safety cabinet on a base stand
  • Base stands: fixed or adjustable height, with or without storage below.
  • Controls: airflow alarms, ECM motors for lower energy use, and filter-life monitoring.

Allow clearance above the cabinet for filter service and exhaust, and check door and elevator sizes for delivery; a 6 ft cabinet on its stand is a large, heavy item. Budget ranges are in our safety cabinet cost guide.

Hospital and Research Applications

Medical lab technologist seated on an ergonomic lab chair working at a biosafety cabinet in a hospital lab

Microbiology and clinical specimen processing. Class II Type A2 cabinets are the standard in hospital microbiology for culture set-up and for processing respiratory, wound and blood culture specimens. Most hospital micro labs need two to four cabinets depending on volume.

Virology and molecular diagnostics. Nucleic acid extraction from clinical specimens is done in a BSC, with separate pre- and post-amplification areas to prevent cross-contamination.

Cell therapy and stem cell processing. Hospital cell therapy labs use Class II cabinets to process bone marrow, cord blood and CAR-T products under aseptic conditions; cleanroom-grade cabinets can be integrated with cleanroom furniture.

Pharmacy compounding. Biological safety cabinets serve as primary engineering controls for hazardous drug compounding under USP <800>, placed in negative-pressure rooms. See hospital pharmacy and compounding furniture.

Research and biotech. Cell culture, gene therapy and vector work at BSL-2, with flammable storage for ethanol and isopropanol nearby. See also hospital and clinical lab furniture and hospital microbiology lab furniture.

Planning the Room Around a Biosafety Cabinet

Where a cabinet sits affects how well it contains aerosols. Cross-drafts from doors, supply diffusers and people walking past can break the air curtain at the front opening.

Placement checklist

  • Keep cabinets away from doors, high-traffic aisles and supply air diffusers.
  • Leave clearance behind and above the cabinet for service and filter changes.
  • Give the operator a stable, adjustable-height chair and a foot rest.
  • Plan a dedicated circuit, and an exhaust connection for canopy or hard-ducted models.
  • Place the autoclave, sink and handwashing within the BSL-2 room as required.

For sinks, airflow, finishes and autoclaves, read our guide to BSL-2 lab design requirements.

Certification, Testing and Decontamination

NSF/ANSI 49 calls for field certification of every biosafety cabinet at installation, at least once a year, and after any move, repair or HEPA filter change. Tests include:

  • HEPA filter integrity (aerosol challenge)
  • Inflow velocity
  • Downflow velocity and uniformity
  • Airflow smoke patterns and cabinet integrity
  • Electrical safety and alarm function
Technician measuring inflow velocity at the front opening of a biosafety cabinet during certification
Lab technician wiping the interior work surface of a biosafety cabinet with disinfectant

Daily surface disinfection keeps the work zone clean; gaseous decontamination is needed before filter changes, moves or major repairs. Labs USA can connect you with certified field technicians for testing and decontamination.

Learn the difference between routine wiping and full fumigation in our biosafety cabinet decontamination guide.

Get a quote on biosafety cabinets

Tell us your biosafety level, the class and width you need, and how many cabinets. We will quote the right models, base stands, exhaust connections and delivery for your lab. Some common sizes are in stock at select manufacturers, subject to confirmation.

Working Safely in a Biological Safety Cabinet

A certified cabinet only protects people when it is used correctly. These practices follow BMBL Appendix A and the guidance most university biosafety offices give their labs.

Before, during and after work

  • Purge first. If the cabinet was shut off, run the blower at least five minutes before starting so suspended particles are cleared (BMBL).
  • Wipe down. Disinfect the work surface, side walls and inside of the sash before and after work. If you use bleach, follow with a sterile-water wipe so chlorine does not corrode the stainless steel.
  • Keep grilles clear. Never block the front or rear grille with paper, wrappers or pipettors. Work at least four inches in from the front grille.
  • Load only what you need. Extra supplies disrupt airflow. Keep clean items and dirty items apart and move your arms slowly in and out.
  • No open flames. A burner creates turbulence in the HEPA downflow. Use an electric loop sterilizer or disposable loops instead.
  • Don’t rely on UV. UV lamps must not be the only disinfection method. If installed, keep them clean, check output with a UV meter and turn them off when people are in the room.
  • One person per cabinet. Cabinets are tested for a single operator; more than one requires a separate risk assessment.
Standard or guideWhat it covers
NSF/ANSI 49North American design, construction, performance and field-certification standard for Class II cabinets
CDC/NIH BMBL, Appendix ASelection, installation and safe use of BSCs by biosafety level
EN 12469European performance standard for microbiological safety cabinets

Choosing a Biosafety Cabinet: Buyer Checklist

Esco Labculture Class II biological safety cabinet on a base stand with sliding sash

Before we quote, we work through the same questions a biosafety officer will ask:

  • Which agents and procedures, and at what biosafety level?
  • Any volatile chemicals or radionuclides? That decides A2 recirculating, A2 canopy or ducted B2.
  • How many people work at once, and which width (3, 4, 5 or 6 ft) fits the room?
  • Is there building exhaust capacity for a ducted cabinet?
  • Will the cabinet fit through doors, elevators and corridors on delivery day?
  • What services go inside: vacuum, gas, outlets, IV bar?
  • Who will certify it at installation and every year after?

Related Clean-Air Workstations in the Labs USA Store

These laminar flow and PCR workstations protect the sample, not the operator, so they are not biosafety cabinets and must not be used with infectious agents. For Class I, II or III biosafety cabinets, request a quote and we will match the model to your biosafety level.

Biosafety Cabinet FAQs

What is the difference between a biosafety cabinet and a fume hood?
Biosafety cabinets use HEPA-filtered airflow to protect workers from biological hazards and, in Class II and III, protect the sample too. Fume hoods exhaust chemical vapors and provide no product protection. Never use a fume hood for biological work or a standard BSC for volatile chemicals.
What class of biosafety cabinet do I need?
Most clinical and research labs use a Class II Type A2 cabinet, which protects personnel, product and environment for BSL-2 work. Choose a ducted Type B2 when volatile chemicals or radionuclides are used, and Class III for maximum containment.
How often do biosafety cabinets need to be certified?
NSF/ANSI 49 field certification is required at installation, at least yearly, and after any move, repair or HEPA filter change.
What sizes do biosafety cabinets come in?
Common nominal widths are 3, 4, 5 and 6 feet. Six-foot cabinets suit two users or high-volume work; four-foot cabinets fit smaller rooms.
Does a Class II A2 biosafety cabinet need to be ducted?
Not usually. A2 cabinets recirculate most air and can exhaust to the room. A canopy (thimble) connection is used when small amounts of volatile chemicals are involved. Type B cabinets must be hard-ducted.
What biosafety cabinet do hospital labs use?
Hospital microbiology and clinical labs mostly use Class II Type A2 cabinets. Hospital pharmacies compounding hazardous drugs use Class II cabinets as primary engineering controls under USP 800, typically ducted to the outside.
Is a laminar flow hood the same as a biosafety cabinet?
No. A laminar flow clean bench blows filtered air toward the user and protects only the product. It must never be used with infectious or hazardous materials.
How much does a biosafety cabinet cost?
A new Class II Type A2 cabinet typically costs $8,000 to $20,000; Type B2 and Class III cost more. See our safety cabinet cost guide for details.
Which biosafety level requires a biological safety cabinet?
Under the CDC/NIH BMBL, BSL-2 labs use a BSC for any procedure that can create infectious aerosols or splashes, BSL-3 labs do manipulations of infectious material in a BSC or other containment, and BSL-4 labs use Class III cabinets or Class II cabinets in a suit laboratory. At BSL-1 a cabinet is optional.
Should I use the UV lamp in a biosafety cabinet?
UV lamps should never be the only way you disinfect a cabinet. BMBL guidance says that if a UV lamp is installed, it must be cleaned and checked with a UV meter regularly and turned off when the room is occupied. Wiping surfaces with a suitable disinfectant is the primary method.
How long should a biosafety cabinet run before use?
If the cabinet has been shut off, run the blower for at least five minutes before you start work so the cabinet can purge suspended particles, per BMBL Appendix A. Then wipe down the work surface and interior walls.