Home / Shop

Isola EDGE Filtered Fume Hood with EverSafe III Touch Microprocessor controller. 110V

$6,240.00
Isola EDGE Filtered Fume Hood with EverSafe III Touch Microprocessor controller. 110V
Isola EDGE Filtered Fume Hood with EverSafe III Touch Microprocessor controller. 110V
Isola EDGE Filtered Fume Hood with EverSafe III Touch Microprocessor controller. 110V
Isola EDGE Filtered Fume Hood with EverSafe III Touch Microprocessor controller. 110V
Isola EDGE Filtered Fume Hood with EverSafe III Touch Microprocessor controller. 110V
Isola EDGE Filtered Fume Hood with EverSafe III Touch Microprocessor controller. 110V
Isola EDGE Filtered Fume Hood with EverSafe III Touch Microprocessor controller. 110V
Isola EDGE Filtered Fume Hood with EverSafe III Touch Microprocessor controller. 110V

Home / Shop

Isola EDGE Filtered Fume Hood with EverSafe III Touch Microprocessor controller. 110V

$6,240.00
Model Number: mystaire-isola-edge-fume-hood
Isola EDGE Filtered Fume Hood with EverSafe III Touch Microprocessor controller. 110V was designed and engineered to provide the end user with superior filtration while offering the same conveniences found on traditional laboratory hoods. The main chamber is dual-wall thermally-fused solid polypropylene allowing the installation of common laboratory fixtures and electrical outlets, if needed.
Missing Option: Size (Select One)
Loading Available Options
Missing Option: Gas Phase Filter
Loading Available Options
Missing Option: Add HEPA Filter
Loading Available Options
Missing Option: Add Dual Purpose Safety Filter
Loading Available Options
Missing Option: Add Pre-Filter Pack of 12
Loading Available Options
Maximum quantity exceeded
Minimum purchase amount of 0 is required
Maximum purchase amount of 0 is allowed
Your Price: $6,240.00
6240.000
A one-time price of $6,240.00 will be added to your order.
*A handling fee of $1,200.00 per item will be added to your shipping total at checkout.
Categories: Fume Hoods
Manufacturer: MyStaire Inc
Facebook
Twitter
Email
Pinterest
Google+
LinkedIn
MySpace
Digg
Delicious
  • Description

Isola EDGE Filtered Fume Hood with EverSafe III Touch Microprocessor controller. 110V

Isola EDGE Filtered Chemical Workstation was designed and engineered to provide the end user with superior filtration while offering the same conveniences found on traditional laboratory hoods. The main chamber is dual-wall thermally-fused solid polypropylene allowing the installation of common laboratory fixtures and electrical outlets, if needed.

The main chamber, made from structural polypropylene, offers superior chemical resistance while the contoured entry foil provides both spill containment and smooth airflow dynamics. The angled and rolled entry design of the Isola EDGE promotes a smooth, turbulent-free work area which reduces eddy currents that affect containment.

Isola PRO Filtered Fume Hood with EverSafe III Touch Microprocessor controller. 110VISOLA Series Filtered Workstations

Isola Series Filtered Workstations are a series of ductless enclosures that offer industry-leading controls, filtration, and safety features to meet and exceed today’s laboratory challenges.

 

 

 

 

 

Features

  • Three models: Isola VUE, Isola PRO and Isola EDGE
  • Three widths: 36”, 48”, 72”
  • Polypropylene and/or polycarbonate construction
  • EversafeIII Touchscreen controller
  • Isola Filtration Matrix -three stage filtration
  • Stand or Bench Mounted
  • Ships Fully Assembled
  • Conforms to UL, CSA & CE

Isola EDGE Fume Hood

  • Dual Wall Polypropylene Construction
  • Allows for service fixtures and sinks and outlets
  • Similar Applications to Isola Pro
  • Research Chemistry
  • Chemical mixing/weighing
  • Chemical disposal/waste

Isola Fume Hoods How It worksHow it Works?

  1. Laboratory room air enters into Isola™
  2. The contaminants are mixed with laboratory air
  3. Contaminated air is filtered through either gas-phase carbon filtration or mechanical filtration
  4. Air is constantly monitored for filter breakthrough as well as temperature and humidity
  5. Air passes through the safety filtration zone before returning to the laboratory

 

 

 

Isola Series Filtration MatrixIsola Series Filtration Matrix

  • Isola Series Filtration Matrix is comprised of three unique and separate zones:
    • Zone 1
  • Pre-Filtration Zone
    • Zone 2
  • Main/Primary Filtration Zone
    • Zone 3
  • Safety Filtration Zone

EverSafeIII™ touch screen controller

 

 

Isola Fume Hood EverSafe III touch screen controller

  • Precise airflow monitoring and adjustment
  • Constant filtration bed monitoring
  • Face velocity readout in LFM or M/SEC
  • Filtration Saturation Indicator
  • One-Touch control of fan and fluorescent light
  • Energy Consumption Meter
  • Temperature and humidity sensor

 

 

Why Isola Fume Hood?

  • Construction
  • Polycarbonate or polypropylene
  • Filtration
  • 3 Stage Filtration Matrix
  • EverSafeIII Touch Screen Controller –Standard
  • 18 Control Icons that allow customers to view or modify
  • Multi application ability with one series of hoods