Wall Mounted Extraction Arms for a University Micro and Nanotechnology Teaching Lab: University of Louisville

The University of Louisville needed fume capture at two teaching bench stations in its Micro and Nano Technology Center. Labs USA supplied wall mounted chemistry extraction arms with powder coated capture hoods, sized to reach the work without taking bench space.

White articulated extraction arm on a wall bracket reaching over a workbench in a university micro and nanotechnology laboratory

The Situation

The University of Louisville runs its Micro and Nano Technology Center as a shared research and teaching facility. Work at that scale involves small volumes of aggressive chemistry: etchants, solvents, developers, and cleaning agents used in fractions of a litre at a time on a bench, often with a group of students watching or taking turns.

Teaching changes the ventilation problem. In a research lab, one experienced person works at a station they know well. In a classroom setting, several people rotate through the same bench, they are learning the procedure rather than performing it from habit, and an instructor needs to see what is happening. Any capture solution that hides the work or that only one person can stand at is working against the purpose of the room.

The benches were already installed and in use, which ruled out reorganising the room. Bench top space in a shared facility is contested at the best of times, and a floor standing extractor parked at a teaching station is an obstacle in a room where people move around each other. Whatever was added had to attach to the building and stay out of the way when it was not needed.

The last constraint was reach. Two specific stations needed capture, and the release points at those stations are not always in the same spot. A fixed hood over a fixed position only works if the work never moves, which in a teaching lab it always does.

The Solution

Labs USA supplied two wall mounted chemistry extraction arms, each a three inch diameter arm at forty three inches long, mounted on its own wall bracket with a white powder coated aluminum capture hood.

Close view of a white three inch diameter articulated laboratory extraction arm with a white powder coated aluminum capture hood on a wall bracket
Three inch chemistry arm on a wall bracket with a powder coated aluminum hood.

The arm is specified as a chemistry arm rather than a general purpose one, which matters when the air being pulled through it contains acid and solvent vapor rather than welding smoke or dust. Materials in the airstream have to tolerate what the lab actually uses. At forty three inches, the arm reaches across a standard bench depth and returns compactly, and the articulated joints hold position where the operator leaves them instead of drifting back during a procedure.

Mounting on wall brackets rather than the bench keeps the entire work surface usable. Nothing is bolted through the top, no leg or stand occupies floor space beside the station, and the arm folds back toward the wall when the bench is being cleared or used for something else. In a shared teaching facility that reversibility is important: the room gets reconfigured between courses and semesters, and equipment that only works in one layout ends up removed.

The capture hoods are powder coated aluminum, which is light enough that the arm holds position easily and rigid enough to keep its shape in a room where people reposition it many times a day. White finish matched the laboratory interior and, more practically, shows contamination rather than hiding it.

Two stations were fitted rather than the whole room. That is a deliberate approach to source capture: put the extraction where the vapor is actually released, instead of raising general exhaust across a room where most benches are doing dry work. It also gives the department a template it can extend station by station as courses change, which is exactly how wall mounted extraction arms tend to be adopted in academic buildings.

Features

🛠

Chemistry Extraction Arms

Three inch diameter arms specified for acid and solvent vapor rather than dust or smoke.

📏

Forty Three Inch Reach

Long enough to cross a standard bench depth, compact enough to fold clear.

📌

Wall Bracket Mounting

Mounted to the wall, so no bench top is lost and no floor space is occupied.

⚪

Powder Coated Hoods

Light, rigid aluminum hoods in a white finish that shows contamination.

👥

Open Sight Lines

Students and instructors can see the procedure, unlike an enclosed hood.

🔄

Repositionable

Articulated joints hold position and let the hood follow the work between demonstrations.

Advantage

A teaching laboratory has three ways to control vapor at a bench station: build another fume hood, raise general room exhaust, or capture at the source. A fume hood is the right answer for extended work with significant quantities, but it is expensive, it consumes a large volume of conditioned air continuously, it takes floor space a shared facility does not have, and it separates a class from the demonstration behind a sash.

Raising general room exhaust is the least targeted option. It moves a very large volume of air to dilute a very small volume of vapor, and it still allows that vapor to travel past a person’s breathing zone before it is removed. In a teaching room where several people stand around one bench, that path matters.

Source capture removes vapor within inches of where it is released, using a fraction of the airflow, while leaving the work visible and reachable for a group. That is why extraction arms are standard equipment in university teaching labs. Where benches sit away from walls, ceiling mounted arms do the same job from above, and Labs USA also supplies laboratory fume hoods and lab furniture when a station needs full enclosure instead.

Benefits

  • Vapor is captured at the bench, before it reaches a student’s or instructor’s breathing zone
  • No bench top space was lost and no floor space was occupied at either station
  • The work stays visible, which matters when a class is watching a procedure
  • Arms fold back to the wall so benches can be cleared between courses
  • Far less conditioned air is exhausted than with a hood or higher general room exhaust
  • Existing casework and room layout were untouched, so no construction downtime
  • The approach extends station by station as the department’s course mix changes
University research laboratory workbench with microscopes and equipment and an extraction hood positioned above the work area

Capture was fitted at the two stations where vapor is actually released, rather than across a room where most benches are doing dry measurement and inspection work.

Return on Investment

The first return is operating cost. Every cubic foot of air a laboratory exhausts is conditioned air the building paid to heat, cool, and dehumidify. Kentucky’s humid summers and cold winters make that cost real. Two extraction arms exhaust a small targeted volume compared with an additional fume hood running continuously, and that difference repeats every hour the building is occupied.

The second is capital avoided. Adding a fume hood to an existing teaching lab is rarely just the hood: it usually means ductwork, a fan, electrical work, casework modification, and a period where the room is out of service. Wall mounted arms attach to existing structure above existing benches and leave the room in service.

The third is teaching capacity. A station that a group can gather around, see, and use is worth more in a teaching facility than a station where one person works behind a sash. Keeping bench tops clear and the room reconfigurable protects the flexibility a shared academic facility depends on.

The fourth is maintainability. Arms, hoods, joints, and dampers are individually replaceable components. A university maintains this kind of system piece by piece rather than budgeting for a wholesale replacement.

Project Process

1

Identify the Stations

Confirm which benches release vapor and which are dry measurement work.

2

Match the Arm to the Chemistry

Specify chemistry rated arms for acid and solvent vapor rather than general purpose.

3

Check Reach and Mounting

Confirm wall structure and bench depth so each arm covers its work zone.

4

Select the Hood

Choose a hood size and finish suited to open bench work and frequent handling.

5

Supply as a Set

Deliver arms, brackets, and hoods together so nothing is missing at install.

Serving Universities and Research Labs Across Louisville and Kentucky

This installation is at the University of Louisville in Louisville, Kentucky. University research buildings present a particular kind of laboratory problem: the buildings are long lived, the science inside them changes every few years, and the ventilation infrastructure was designed around what the building did when it opened. Retrofitting capture at specific benches, without touching the base building systems, is often the only practical way to keep those rooms current.

Labs USA supplies extraction arms, fume hoods, laboratory casework, work surfaces, balance tables, and cleanrooms to universities, research institutes, and industrial laboratories in Louisville, Lexington, Bowling Green, Covington, and across Kentucky and the Ohio Valley, and works on laboratory projects nationwide. Academic clients usually buy in small increments tied to a course or a grant, so equipment that can be added station by station fits how they actually fund work.

Related work includes exhaust snorkels and extraction arms in wall, ceiling, and portable forms, laboratory fume hoods for enclosed chemical work, lab furniture and casework for teaching benches, and laboratory tables for instrument and weighing stations.

Shop Wall-Mounted Exhaust Snorkels Online

The same in-stock articulating arms used in this university lab installation, order online or request a quote for multi-arm lab layouts.

Exhaust Snorkel OriginalExhaust Snorkel OriginalAll-around articulating arm with dome hood for general fume and dust capture. · $1,260
Exhaust Snorkel ESD/EXExhaust Snorkel ESD/EXConductive-material arm that eliminates static buildup and spark risk near solvents. · $1,450
Exhaust Snorkel Chemical ResistantExhaust Snorkel Chemical ResistantCorrosion-resistant arm built for aggressive-chemical environments. · $1,535

Planning Around a Research Calendar

One detail shaped this project more than any specification: extraction arms are made to order. There is no warehouse shelf to pull them from, so the delivery date is not a formality at the end of the process, it is an input to the research schedule at the start of it.

In a university laboratory that matters differently than in a production facility. Research groups book instrument time, graduate students plan experiments around equipment availability, and a semester is a hard boundary. When the arm arrives three weeks later than assumed, the cost is not freight, it is a delayed experiment.

What we would tell any university lab planning the same work

  • Ask for the made-to-order lead time in writing at quote stage and build the research schedule backwards from it, rather than treating the quote date as the start.
  • Confirm the mounting hardware is on the quote. A wall bracket identified after the order is placed adds a second quote cycle and pushes the date again, which is the most common late change on extraction arm orders.
  • Get the internal engineering or facilities review done while the arm is in production rather than after it arrives, so installation can start the week it lands.
  • Where a semester boundary is fixed, say so. It changes what we recommend on configuration, because some options carry longer lead times than others.

None of this changes the hardware. It changes when the laboratory can actually use it, which is the part researchers care about.

Frequently Asked Questions

What is a chemistry extraction arm?

An articulated source capture arm built with materials that tolerate acid and solvent vapor, as opposed to general purpose arms intended for dust, smoke, or welding fume.

Why wall mounted rather than bench mounted?

A wall bracket keeps the entire bench top usable and leaves no leg or base on the floor. It also lets the arm fold back out of the way when the station is used for something else.

How far should an extraction arm reach?

Far enough to cover the work zone of the bench it serves. A forty three inch arm crosses a standard bench depth, which is what these two teaching stations needed.

Are extraction arms a substitute for a fume hood?

No. Hoods enclose extended work with larger quantities. Arms capture vapor at a specific release point on an open bench, using much less air, and keep the work visible.

Do extraction arms work in teaching laboratories?

They suit teaching particularly well, because a group can gather around an open bench station and see the procedure, which is not possible behind a sash.

How much air does an extraction arm exhaust?

Far less than a fume hood or an increase in general room exhaust, because it removes vapor within inches of the source instead of diluting it across the room.

Can arms be added to an existing laboratory without renovation?

Yes. They mount to existing wall structure above existing benches, so no casework is modified and the room stays in service.

Can more stations be added later?

Yes. Source capture is modular by nature, so a department can fit two stations now and extend as courses and research programs change.

Adding Fume Capture to a Teaching or Research Lab?

Labs USA specifies wall, ceiling, and portable extraction for existing laboratories, plus fume hoods and casework when a station needs full enclosure.