A laboratory fume hood is a critical safety device found in nearly every modern lab. It is much more than a simple cabinet with a window. It acts as a primary line of defense to protect researchers from hazardous materials. Think of it as a ventilated enclosure designed to pull harmful fumes, vapors, and dust away from the user and exhaust them safely out of the lab.

The main purpose of a fume hood is containment. When you handle volatile chemicals or work with reactions that produce toxic gases, the hood creates a controlled workspace. It uses a fan to create a directional airflow. This pulls contaminated air from the lab, through the hood, and into the building's exhaust system. This process prevents dangerous substances from reaching the breathing zone of a lab technician.

You will find fume hoods in many settings. These include university chemistry labs, pharmaceutical research facilities, and industrial quality control labs. A fume hood is essential anytime there is a risk of releasing hazardous airborne materials. It is a key requirement for keeping people safe.


TL;DR: What Is a Fume Hood Used For?

A fume hood is a ventilated enclosure that protects lab workers from inhaling hazardous fumes, vapors, and dust. It works by pulling contaminated air from the workspace and safely exhausting it outside the building or through filters. This creates a safe breathing zone for the user. It also provides a physical shield against chemical splashes, fires, and runaway reactions. Fume hoods are essential safety equipment in chemical, pharmaceutical, academic, and industrial laboratories.


Understanding How a Fume Hood Protects You

A fume hood acts as your personal safety shield in the lab. It is the first line of defense for the air you breathe. Its main job is to capture hazardous fumes, vapors, and dust from your experiments before they can escape into the room.

A fume hood in a lab demonstrating containment flow with white smoke and a flask.

It does this by pulling a continuous stream of air from the lab, through the work area, and then venting it safely outside. This constant, controlled airflow creates an invisible barrier. This barrier keeps harmful substances contained and away from you.

The Science of Containment

This process relies on a few key parts working together. You can think of it as a controlled wind tunnel for your experiment. The hood creates an inward flow of air called face velocity. This airflow is strong enough to pull contaminants away from your breathing zone and into the exhaust system.

These engineering controls are designed to limit a lab worker’s exposure to hazardous chemicals. A fume hood captures, contains, and exhausts toxic fumes, vapors, gases, and dusts. But it is more than just airflow. The sash and side panels also provide a physical barrier against splashes, reactions, and small fires.

Three key parts make this possible:

  • The Sash: This is the sliding front window. It acts as a physical shield and helps control the face velocity. Keeping it as low as possible while working makes you safer.
  • Baffles: The slotted panels at the back of the hood are the baffles. They ensure the airflow is smooth and even. This prevents dead spots where fumes could build up.
  • The Exhaust Fan: This powerful fan is usually on the roof. It pulls all the contaminated air out of the hood and safely away from the building.

Beyond Chemical Fumes

While fume hoods are mainly for chemical vapors, their protective shell serves other important purposes. The heavy-duty construction and safety glass sash create a physical shield between you and your work.

This barrier protects you from the unexpected, such as chemical splashes, shattering glassware, or small fires. The enclosure helps manage these incidents, stopping them from becoming a larger problem.

Understanding these safety layers is vital. It is also helpful to see how this equipment fits into broader safety plans, like understanding the role of a risk register in health and safety. Every part, from the airflow to the structure, must work correctly. For more details, our guide on fume hood safety covers best practices for using this equipment.

Comparing the Different Types of Fume Hoods

If you visit a few different labs, you will see that not all fume hoods are the same. Choosing the right one is about matching the equipment to the specific work being done. Getting this right is critical for keeping your lab safe and your experiments running well.

Let's look at the most common types of laboratory fume hoods and what makes each one unique.

A row of various laboratory fume hoods in a lab, with blue and white cabinets below.

We will start with ducted hoods, which vent contaminants outside. Then we will look at flexible ductless models, which use filters to clean the air.

Ducted Fume Hoods

When you imagine a classic lab fume hood, you are likely thinking of a ducted model. These are the traditional standard for a good reason. They work by pulling contaminated air from inside the hood and pushing it out of the building through ductwork.

This direct exhaust method offers strong, broad-spectrum protection. This makes ducted hoods the top choice for labs handling a wide variety of volatile or highly toxic chemicals. They do not depend on filters that can become saturated. This means you get consistent, reliable safety. The downside is that they require significant infrastructure and can be more expensive to run since they constantly pump conditioned lab air outside.

Ductless Fume Hoods

A ductless fume hood works differently. Instead of venting air outside, it draws contaminated air through a filter stack. This stack usually has activated carbon and sometimes HEPA filters. Then, it recirculates the clean air back into the room.

The biggest advantage is flexibility. You can place a ductless hood almost anywhere without needing expensive ductwork. This makes them perfect for labs where external ventilation is difficult or impossible. They are also often more energy-efficient.

However, they are only suitable for specific, low-volume chemical uses. You must know exactly which chemicals you will use because the filters are designed for certain compounds. If this versatile solution seems right for you, explore various ductless fume hoods to see the options.

Specialized Hoods and Cabinets

Beyond the two main types, some specialized units are built for very specific jobs. You will not see these in every lab, but they are essential for certain tasks.

  • Walk-In Hoods: These are large, floor-mounted enclosures big enough for large equipment or complex experimental setups.
  • Powder Hoods: These are designed specifically to contain fine particles during weighing or mixing.
  • Biological Safety Cabinets (BSCs): BSCs are often mistaken for fume hoods, but they have a different purpose. A BSC uses HEPA filters to protect the user, the environment, and the sample from biological contaminants like bacteria and viruses. They are not designed for use with hazardous chemicals.

Comparison of Common Fume Hood Types

Feature Ducted Fume Hood Ductless Fume Hood Biological Safety Cabinet
Primary Protection User from chemical fumes User from specific chemical fumes User, sample, and environment
Air Handling Vents air outside Filters and recirculates air Filters and recirculates or vents air
Best Used For Wide range of toxic chemicals Low volume, known chemicals Biological agents, cell cultures
Limitations Requires complex installation Limited chemical applications Not safe for volatile chemicals

As you can see, the choice is not just about cost. It is about understanding your work and selecting the equipment designed to handle those specific risks.

Decision Scenarios: Choosing the Right Hood for the Job

To understand what a fume hood is for, it helps to see how they are used in different situations. Here are a few mini-guides to help you decide.

  1. Scenario: University Chemistry Teaching Lab

    • Challenge: Students perform a wide range of experiments with strong acids, bases, and organic solvents. The types of chemicals used can change each semester.
    • Solution: A standard ducted fume hood is the best choice. It can handle a broad spectrum of chemicals safely and reliably, making it ideal for the varied and unpredictable nature of a teaching environment.
  2. Scenario: Pharmaceutical Quality Control (QC)

    • Challenge: A technician needs to weigh small, consistent amounts of a non-volatile, potent powder for daily sample testing.
    • Solution: A ductless powder hood (also known as a balance enclosure) is perfect. It provides excellent containment for powders without the need for external ducting, and its carbon filter can handle the minimal solvent vapor used for cleaning.
  3. Scenario: Mobile or Temporary Lab Setup

    • Challenge: A company needs to set up a temporary testing site in a rented office space where installing new ductwork is not an option. They will only be working with low volumes of rubbing alcohol.
    • Solution: A ductless fume hood is the only practical option. As long as the filter is rated for alcohol vapors and usage is light, it offers the needed protection with maximum flexibility.
  4. Scenario: Large-Scale Chemical Synthesis

    • Challenge: A research team is scaling up a chemical reaction that involves a large glass reactor and several heating mantles. The process releases corrosive acid vapors.
    • Solution: A walk-in fume hood is necessary. Its large size can accommodate the entire experimental setup, ensuring all fumes from the large-scale reaction are safely contained and exhausted.
  5. Scenario: Cell Culture and Virology Research

    • Challenge: A biologist is working with infectious viral strains and needs to protect both themselves and their sensitive cell cultures from contamination.
    • Solution: A Biological Safety Cabinet (BSC) is the only correct choice. It provides a sterile work environment to protect the sample while using HEPA-filtered air to protect the user and the lab environment from biological agents. A chemical fume hood would not protect the sample.

How to Choose the Right Fume Hood for Your Lab

Picking the right fume hood is a major decision for any lab. This choice directly impacts your team's safety, your daily work efficiency, and your budget. With so many options, a structured approach makes all the difference.

Follow this five-step checklist to select a fume hood that truly protects your people and processes.

Your 5-Step Selection Checklist

This guide will walk you through the essential factors, from the chemicals you handle to your facility's layout.

  1. Define Your Chemical Use
    First, what exactly will you be working with? List every chemical that will be handled inside the hood. Are they corrosive acids, volatile solvents, or fine powders? This information determines the necessary liner material and tells you if a specialized hood is required.

  2. Evaluate Your Facility and Space
    Next, look at your lab’s infrastructure. Do you have existing ductwork running outside? If so, a ducted hood is a natural choice. If not, a ductless model may be more practical. Measure your available space, leaving enough clearance for maintenance and movement. A standard bench top fume hood is often a good fit, but only if you have room for it.

  3. Calculate Airflow and Energy Needs
    Your two main options for ventilation are Constant Air Volume (CAV) and Variable Air Volume (VAV) systems. A CAV system exhausts the same amount of air all the time. A VAV system adjusts airflow based on sash height. While a VAV system costs more initially, it can save a lot on energy bills. Your choice depends on your budget and sustainability goals.

  4. Identify Special Requirements
    Now, consider the details. Does your work demand unique features? For instance, working with perchloric acid requires a wash-down system in the hood. Do you need service fixtures like gas, vacuum, or water lines installed inside the hood? It is cheaper to plan for these additions now than to add them later.

  5. Confirm Safety and Compliance
    Finally, you must verify that your chosen hood meets all necessary industry safety standards. The most important one is ASHRAE 110, which tests a hood’s containment performance. Compliance is a non-negotiable confirmation that the fume hood will protect your staff. Always ask the manufacturer for certification documents.

Mastering Fume Hood Safety and Operation

A fume hood is only as effective as the person using it. Think of it as an active safety system, not just a piece of furniture. You need to operate it correctly for it to protect you.

Following a few essential best practices is mandatory for lab safety. These simple habits make the difference between true containment and a false sense of security.

Scientist in lab coat, mask, and safety glasses working safely inside a fume hood.

Core Operating Procedures

To keep a fume hood working as designed, everyone in the lab must follow a few key rules. These habits minimize air turbulence and maximize the hood’s ability to pull contaminants away from you.

  • Work at Least Six Inches Inside: Always keep your equipment and chemicals at least six inches back from the face of the hood. This buffer zone prevents hazardous fumes from escaping into your breathing space.
  • Keep the Sash Low: Work with the sash as low as is practical. A lower sash provides a physical barrier and increases the airflow velocity, making containment more effective.
  • Avoid Rapid Movements: Sudden movements in front of the hood or walking quickly past it can disrupt the air curtain. Move slowly and deliberately to maintain a stable barrier.
  • Do Not Use for Storage: A fume hood is not a storage cabinet. Storing chemicals or equipment inside it blocks airflow, reduces efficiency, and creates a serious fire or reaction hazard.

Monitoring and Maintenance

You cannot just assume your fume hood is working correctly. It requires regular checks and maintenance to ensure it continues to provide protection.

  • Daily Checks: Before each use, visually inspect the hood. Check the airflow monitor to ensure it is reading in the safe range. Make sure the baffles are not blocked.
  • Annual Certification: Have your fume hoods professionally tested and certified at least once a year. This test confirms that the face velocity and containment meet safety standards like ASHRAE 110.
  • Regular Cleaning: Keep the hood interior and sash clean. Spills should be cleaned up immediately following your lab's safety protocols. Always consult the Safety Data Sheet (SDS) for the spilled chemical.

By combining proper technique with consistent monitoring and maintenance, you ensure your fume hood performs its most important job: keeping you safe.

Frequently Asked Questions About Fume Hoods

Here are straightforward answers to common questions about fume hoods. This information helps clear up confusion and reinforces safety basics.

1. What is the main difference between a fume hood and a biosafety cabinet?

A fume hood protects the user from chemical fumes by venting air outside. A biosafety cabinet (BSC) uses HEPA filters to protect the user, the sample, and the environment from biological agents. They are not interchangeable. Never use a BSC for volatile chemicals.

2. How often does a fume hood need to be certified?

A fume hood must be professionally tested and certified at least once per year. It also needs recertification after it is installed, moved, or has had major repairs.

3. What is the ideal face velocity for a fume hood?

The ideal face velocity is generally between 80 and 120 feet per minute (FPM), or 0.4 to 0.6 m/s. If the velocity is too low, contaminants can escape. If it is too high, it can create turbulence that also causes spills. Your facility's Environmental Health and Safety (EHS) office sets the specific requirement for your lab.

4. Can I store chemicals inside a fume hood?

No. A fume hood is for active work, not storage. Storing items inside blocks airflow, creates dead spots where fumes can build up, and increases the risk of spills and fires. Chemicals should be stored in approved safety cabinets.

5. Why do I need to work six inches inside the hood?

Working at least six inches from the sash opening creates a buffer zone. This ensures that any air turbulence at the front of the hood does not cause hazardous fumes to escape into your breathing zone. It is a critical rule for effective containment.

6. What should I do if the fume hood alarm sounds?

If the airflow alarm sounds, it means the face velocity is outside the safe range. Lower the sash to the lowest practical working height immediately. Stop your work, cap all containers, and notify your lab supervisor or EHS department. Do not use the hood until it has been inspected and cleared for use.

7. What are fume hoods made of?

The materials depend on the intended use. The exterior is typically steel. The interior liner is often made of epoxy resin, phenolic resin, or stainless steel to resist corrosion from specific chemicals. The sash is made of laminated safety glass.

8. Are ducted or ductless fume hoods better?

Neither is universally "better." Ducted hoods offer broader chemical protection and are the standard for heavy use. Ductless hoods offer flexibility and energy savings but are limited to specific, low-volume chemicals that their filters can handle. The best choice depends entirely on your application and facility.

Conclusion

Understanding what a fume hood is used for is the first step toward a safer laboratory. This essential equipment serves as a primary engineering control, capturing dangerous fumes and providing a physical shield against hazards. By choosing the right type of hood for your specific applications and following proper operating procedures, you create a secure environment for your team.

Safety is an active process. Regular maintenance, annual certifications, and consistent training ensure your fume hood remains a reliable partner in your work.

Ready to improve your lab's safety and efficiency?

Written by 

We are a full service Shelving, Storage system and Material Handling equipment supplier. We offer many options to increase space, productivity and save you money. Give us a call or an free analysis of your space. Get started today! 801-328-8788